Interra
-
Interra 160mA KNX power supply ITR900-116
Interra 160mA KNX power supply ITR900-116 :
- Mounting Location: Installation only on a 35 mm DIN rail of a distribution board.
- Device needs at least 4 standard modules width at installation.
- Power supply has an additional 30 VDC short circuit and overload protected voltage output that can be used to power an additional bus line (in combination with a separate choke).
- The voltage output is overload, short circuit and over temperature protected.
- Output without choke can be used as a constant 30 VDC supply and output with choke can be used as a KNX Bus supply.
129.00 € -
Interra 2 channels DALI Gateway ITR832-002
Description :
- The ITR832-002 dual channels KNX-DALI interface device is used to provide interface between DALI and KNX installations, enabling communication between the two protocols.
- DALI devices (ballasts, etc. ECGs) connected to the line are supplied with the internal DALI power supply.
- Up to 2x64 DALI ballasts can be connected to the ITR832-002.
- With each DALI channel, 16 groups, 16 scenarios and 64 devices can be controlled. In addition, independent emergency lighting according to EN 62386-202 will be supported with the 2nd version update. Emergency lighting tests (eg function and time test) can be triggered via the KNX line. In addition, feedback on the KNX line can be sent. Each DALI device can be controlled by individually, group or broadcast control.
General functions :
- Automatic DALI Device Addressing.
- Switching, dimming and brightness configure
- Scene configure
- KNX Bus Voltage Failure Status.
- KNX Voltage Recovery Status.
- DALI Bus Voltage Failure Status.
- DALI Voltage Recovery Status.
- Ballast and / or Lighting Error.
- Working log analysis with UDP.
- Broadcast control can be made with manually and software.
- Tunable White colour temperature control.
- RGB and RGBW colour control.
Comminssionning functions :
- Addressing operations can be done via ETS or manual buttons as short address assignment.
- Assigning group adresses to ballasts via ETS without need additional software.
- Faulty ballast detection.
- Faulty lighting detection.
- DALI line device selection with manual button.
- Remote software update via Ethernet connection.
Safety precautions and important notes :
- The device may only be installed and put into operation by a qualified electrician or authorized personnel.
- For planning and construction of electric installations the appropriate specifications, guidelines and regulations in force of the respective country have to be complied.
- Special Programming: This device is designed for professional KNX and DALI installation. It can be programmed by ETS and Web Browser.
- Cable Connections: Ensure making correct connections for Black and Red wires.
- Input Voltage: The input voltage shall be 100-240 VAC.
- Installation only in dry locations and on a 35 mm DIN rail (TH 35).
- For mounting only use an appropriate equipment according to IEC 60715.
- Rain, liquid and aggressive gas should not allowed to be close to device.
- Screw down strength is less than 0.4Nm.
- Do net get AC 240 V voltage into Bus lines, it can damage all of devices in system.
252.00 € -
Interra 2 channels Universal interface ITR102
Interra ITR102 :
Description :
ITR102 device is used to interface the contacts to KNX bus substructure such as push buttons, switches etc. to make them communicating devices.
Configuration and features :
- The complete configuration of the device is performed via ETS3 or higher.
- Depending on ETS configuration and settings the product feature will be different.
- Avaialble functions are:
- Switching
- Dimming
- Toggle
- Blind Control
- 2 Channel
- Value Selected
- Most of functions only need one input and therefore each input might be assigned a different function. However there are also some functions which use two inputs such as “Dimming with 2 buttons” and “Shutter/Blinds with 2 buttons”.
Mounting, commissionning and safety notes :
- The device may only be installed and put into operation by a qualified electrician or authorized personnel.
- The device is inserted in a flush-mounted combined joint box.
- The installation location should not be in the outdoor area.
- The voltage potentials on the lines connecting the contacts are not electrically isolated from the bus voltage.
- Permitted cable length can be up to 5 meters and unused wires should be insulated.
- Avoid contact with liquids and corrosive gases.
- Do not get wrong connection for KNX Black and Red wires.
- Please do not forget to recheck all connections after installation
44.50 € -
Interra 320mA KNX power supply ITR900-132
Interra 320mA KNX power supply ITR900-132 :
- Mounting Location: Installation only on a 35 mm DIN rail of a distribution board.
- Device needs at least 4 standard modules width at installation.
- Power supply has an additional 30 VDC short circuit and overload protected voltage output that can be used to power an additional bus line (in combination with a separate choke).
- The voltage output is overload, short circuit and over temperature protected.
- Output without choke can be used as a constant 30 VDC supply and output with choke can be used as a KNX Bus supply.
171.00 € -
Interra 4 channels Universal interface ITR104
Interra ITR104 :
Description :
ITR104 device is used to interface the contacts to KNX bus substructure such as push buttons, switches etc. to make them communicating devices.
Configuration and features :
- The complete configuration of the device is performed via ETS3 or higher.
- Depending on ETS configuration and settings the product feature will be different.
- Avaialble functions are:
- Switching
- Dimming
- Toggle
- Blind Control
- 2 Channel
- Value Selected
- Most of functions only need one input and therefore each input might be assigned a different function. However there are also some functions which use two inputs such as “Dimming with 2 buttons” and “Shutter/Blinds with 2 buttons”.
Mounting, commissionning and safety notes :
- The device may only be installed and put into operation by a qualified electrician or authorized personnel.
- The device is inserted in a flush-mounted combined joint box.
- The installation location should not be in the outdoor area.
- The voltage potentials on the lines connecting the contacts are not electrically isolated from the bus voltage.
- Permitted cable length can be up to 5 meters and unused wires should be insulated.
- Avoid contact with liquids and corrosive gases.
- Do not get wrong connection for KNX Black and Red wires.
- Please do not forget to recheck all connections after installation
53.50 € -
Interra 6 channels Universal interface ITR106
Interra ITR106 :
Description :
ITR106 device is used to interface the contacts to KNX bus substructure such as push buttons, switches etc. to make them communicating devices.
Configuration and features :
- The complete configuration of the device is performed via ETS3 or higher.
- Depending on ETS configuration and settings the product feature will be different.
- Avaialble functions are:
- Switching
- Dimming
- Toggle
- Blind Control
- 2 Channel
- Value Selected
- Most of functions only need one input and therefore each input might be assigned a different function. However there are also some functions which use two inputs such as “Dimming with 2 buttons” and “Shutter/Blinds with 2 buttons”.
Mounting, commissionning and safety notes :
- The device may only be installed and put into operation by a qualified electrician or authorized personnel.
- The device is inserted in a flush-mounted combined joint box.
- The installation location should not be in the outdoor area.
- The voltage potentials on the lines connecting the contacts are not electrically isolated from the bus voltage.
- Permitted cable length can be up to 5 meters and unused wires should be insulated.
- Avoid contact with liquids and corrosive gases.
- Do not get wrong connection for KNX Black and Red wires.
- Please do not forget to recheck all connections after installation
64.00 € -
Interra 640mA KNX power supply ITR900-164
Interra 640mA KNX power supply ITR900-164 :
- Mounting Location: Installation only on a 35 mm DIN rail of a distribution board.
- Device needs at least 4 standard modules width at installation.
- Power supply has an additional 30 VDC short circuit and overload protected voltage output that can be used to power an additional bus line (in combination with a separate choke).
- The voltage output is overload, short circuit and over temperature protected.
- Output without choke can be used as a constant 30 VDC supply and output with choke can be used as a KNX Bus supply.
189.00 € -
Interra black Just Touch ITR328-1001
Interra Just Touch ITR328-1001 :
• Pushbutton has Switching, toggle, dimming, shutter/blinds, thermostat controls, scenes, value, 2 channels, step switching mode features.
• Locking feature available for each button and complete device
• On/Off (2-points) and Proportional (Continuous or PWM) thermostat functions.
• Comfort, standby, economy and building protection operating modes.
• Manual or Automatic switching between Heating and Cooling modes.
• Temperature measuring through integrated sensor with possibility of sending the value on change and periodically to the bus.
• Temperature (measured, external, setpoint, outdoor values as ºC), CO2 concentration (from bus), humidity percentage, operating modes, fan levels, on/off indicators, warnings and locking status are displayed on screen.
• Fan controller available with different speed indicators.
• Relative humidity measuring through the integrated sensor with possibility of sending the value on the bus.
• Threshold alarm define for temperature, humidity and air quality levels.
• RGB LED control.380.00 €