Siemens
-
Siemens KNX room thermostat - RDF800KN - RDF800KN/VB
Siemens KNX room thermostat - RDF800KN - RDF800KN/VB
Flush mount touch KNX room thermostat for 2-/4-pipe FCU with on/off output and 2x universal input, fit for both round and square conduit boxes
- KNX communications
- Operating modes: Comfort, Economy and Protection
- For heating and/or cooling applications
- 2 or 3-position control outputs
- Output for 1-speed or 3-speed fan
- 2 multifunctional inputs for keycard contact, external room / return air temperature (QAH11.1, QAA32), heat / cool changeover, window contact on/off, dewpoint monitor, electrical heater enabled, fault contact, presence detector
- Automatic or manual heating/cooling changeover
- Adjustable commissioning and control parameters
- Minimum and maximum setpoint limitation
- Color of housing: Ivory white (RAL 9001)
- Backlit display
Application selectable:
- 2-pipe system
- 2-pipe system with electrical heater
- 4-pipe system
234.00 € -
Siemens KNX IP Interface Secure - 5WG1148-1AB23 - N 148/23
Siemens KNX IP Interface Secure -5WG1148-1AB23 - N 148/23
N 148/23
- For communication between KNX devices and PCs or other devices with Ethernet (10BaseT or 100BaseT) interface, for remote access to an KNX installation
- Uses the KNXnet/IP protocol or secured access and data transmission via KNXnet/IP Secure
- Up to five KNXnet/IP Tunneling connections for parallel bus access by ETS and further PC software
- Assignment of the network parameters by the installer using ETS, automatically by a DHCP server in the network
- 5 LEDs for display of availibility, KNX communication and IP communication
- Electronics powered via “Power over Ethernet” according to IEEE 802.3af or alternatively by an external safety extra low voltage power supply for AC/DC 24V
- Pluggable terminal block for connection of external power supply unit (not included)
- Ethernet connection via RJ45 socket
- Housing: plastic, color RAL 7035 (light grey), N-system
- DIN rail mounted device for mounting on rail TH35 according to DIN EN 60715
- Type of protection: IP 20
212.40 € -
Siemens KNX Power supply unit DC 29 V, 640 mA - 5WG1125-1AB22
Siemens KNX Power supply unit DC 29 V, 640 mA - 5WG1125-1AB22
KNX Power supply unit DC 29 V, 640 mA with additional unchoked output, N 125/22
Output current 640 mA
283.20 € -
Siemens KNX Pushbutton interface x4 4e/4s - UP 220D31 - 5WG1220-2DB31
Siemens KNX Pushbutton interface x4 4e/4s - UP 220D31 - 5WG1220-2DB31
KNX Pushbutton interface 4 x potential-free contact, output for LED control
- With 4 inputs / outputs each configurable for potential-free contacts or for control of an LED (max 2 mA)
- With integrated bus coupling unit, bus connection via bus terminal
- 8-wire plug-in cable set, 280 mm long, extendable to a max. of 10 m
- For insertion in flush-mounting switch and socket boxes 60 mm in diameter and 40 mm deep
- KNX PL-Link (Desigo TRA)
- KNX S-Mode (GAMMA)
79.50 € -
Siemens KNX Room operator unit - QMX3.P34 - QMX3.P34-1BSC
Siemens KNX Room operator unit - QMX3.P34 - QMX3.P34-1BSC
Room operator unit KNX with temperature sensor, segmented backlit display, touchkeys, black
-
-
Functions:Additional functionalities GAMMA
- Temperature sensor
- Segmented backlit display and touchkeys
- Temperature control, adjustable as PWM control and/or modulating control (PID algorithm), for pure heating mode, pure cooling mode, heating and cooling mode
- Operating modes switchable via KNX and/or display: Comfort mode, Pre-Comfort, energy savings and protection mode
- Adjustable commissioning and control parameters for radiated heating, slow and fast, floor heating slow and fast
- Integrated bus coupling unit
- 3 independently adjustable switching values for CO2 concentration and relative air humidity for air quality control
- Actuating variable for 1, 2, or 3-stage fans (humidity and CO2)
- Actuating variable for 1, 2, or 3-point positioning signal (humidity and CO2)
- Setpoint for room temperature and relative humidity and CO2 concentration adjustable via KNX
-
132.00 € -
-
Siemens KNX Servo Motor Valve Actuator - SSA118.09HKN
Siemens KNX Servo Motor Valve Actuator - SSA118.09HKN
For pressure independent combi valves (PICV), radiator valves, MiniCombi valves (MCV) and small globe valves.
Electromotoric actuators with KNX S-Mode und PL-Link communication for radiator, chilled ceiling, VAV and fan coil unit applications. With automatic stroke adaption, force-dependent switching off in the end position, LED position indication, and manual operation. Suited for use with Siemens PICV VPP46../VPI46.., Siemens radiator valves VDN../VEN../VUN.., Siemens MiniCombi valves VPD../VPE.., Siemens small valves VD1..CLC and on radiator valves with M30 x 1.5 connection without adapter (Heimeier, Cazzaniga, Oventrop M30x1.5, Honeywell-Braukmann, MNG, Junkers, Beulco new). Further valves of other manufacturers on request.Information complémentaire
For fitting to the valve: Cap nut M30 x 1.5172.80 € -
Siemens KNX Switching actuator 12 x AC 230 V, 10 A - 5WG1532-1DB61
Siemens KNX Switching actuator 12 x AC 230 V, 10 A - 5WG1532-1DB61
KNX Switching actuator 12 x AC 230 V, 10 AX, C-Load
-
N 532D61KNX Switching actuator 12 x AC 230 V, 10 AX, C-Load
Rated contact current according to DIN EN 60669: 10 AX (140 µF fluorescent lamp load), 10 A (resistive load)Additional functionalities GAMMAPer output
- Selectable operating mode (normal mode, time switch mode, flashing mode)
- Selectable relay mode (NC/NO)
- Variable On and Off delay times
- Two selectable logic operations (AND, OR, NAND, NOR, XOR, FILTER, TRIGGER)
- Selectable sending of status objects on request, cyclically and/or automatically after a change
- Selectable switching state on bus voltage failure
- Selectable start value of the switching object on bus voltage recovery
- Optional addition of a night mode object for time-limited switching On of the output, i.e. the illumination, at night
- Variable On period at night or time switch mode
- Selectable addition of an object to change the On period at night or time switch mode
- Selectable post-triggering (1x, 2x, 3x, 4x, 5x) of the On period in time switch mode
- Selectable warning signal prior to imminent switching-off by brief off and on switching (flashing) at night or in time switch mode and/or via an optional warning object
Per output selectable functions:
- For manual override ON
- For permanent OFF switching
- Blocking of the output
- For switching on or off in forced mode
- Counting of operating hours and threshold monitoring
- Counting of load cycles and threshold monitoring
- Integrated 8-bit scene control with up to 8 scenes per output
- Construction site function switching
- Object for monitoring of device function
- Object for targeted retrieval of status values
362.40 € -
-
Siemens KNX Thermal drive actuator-6 x AC 24/230 V - 5WG1605-1DB41
Siemens KNX Thermal drive actuator-6 x AC 24/230 V - 5WG1605-1DB41
- For control of electrothermal valve drives for AC 24...230 V in heating/cooling systems via 6 noiseless semiconductor outputs
- Electronic protection of the outputs against short circuit and overload
- Rated current: 0.5 A per channel and group of 3 outputs
- Max. inrush current (2 sec.): 3.5 A per channel and group of 3 outputs
- Max. inrush current (2 min.): 0.9 A per channel and group of 3 outputs
- Direct operation per channel for opening and closing the valve and activating direct operation
- Red LED per channel to indicate valve open or closed and status of the control value
- Red error LED per channel to indicate overload/short circuit and pover voltage failure
- Maintenance-free terminals for connection and through-wiring of untreated single-core, stranded or multi-core conductors, 0.5 ... 2.5 mm²
- 2 terminals per channel for connecting the electrothermal valve drives
- 2 terminals on the unit for supply of the valve voltage AC 24...230 V
- Bus-powered electronics
- Housing: plastic, color RAL 7035, N-system
- DIN rail mounted device for mounting on rail TH35 according to DIN EN 60715
- Type of protection: IP 20
- Per channel setting of the valve operation direction de-energised open or closed
- Per channel optional control via switching commands or continuous positioning commands
- Per channel control value limitation and adjustment of the valve characteristic for continuous control values
- Per channel control value monitoring
- Adjustable behaviour in case of override (lock, service mode, forced position, forced control)
- Per output automatic, demand-oriented or manual valve rinsing
- Per output operating hours counting and switching cycle counting with limit value monitoring
- Evaluation of control values for heating or cooling demand requirements on a primary system and for controlling heating or cooling circuit pumps
- 6 room temperature controllers for 2-pipe or 4-pipe systems, adjustable as 2-position control or continuous control, for heating-only mode, cooling-only mode, heating and cooling mode, with two-stage heating or cooling
- Output of the control values optionally as switching command On/Off or as continuous control command
- 13 min., max. and weighted value calculators
- 6 logical operations (AND/OR/XOR/TRIGGER/LOCK)
- Surveillance of device function
198.00 €